How It Works: Set up and load your pen

Prep once. Dial. Done.

The old routine: a vial, a fresh syringe, and a careful draw against tiny graduation marks, every single session. The MODTECH routine: fill a sterile cartridge once, load the pen once, and every session after that is the same short routine: fresh tip, quick prime, dial, dispense, back in the fridge.

New pen in hand? Start at section 1 and work down. Each step builds on the one before.

1. Before you start

Everything below assumes your compound is already reconstituted. That part is on you — MODTECH sells hardware only, and nothing is included, prefilled, or sold alongside a pen.

Your order arrives as hardware only. We don't include printed instructions with orders — this Help Center is the manual, so it's always current and we can fix or expand it the day someone asks a good question.

What you'll need

  • Your reconstituted solution.
  • A 3–5 mL transfer syringe. This is what carries the solution into the cartridge.
  • A 1 mL (100U) insulin syringe. This becomes your vent, and it gets thrown away afterward. It is not optional — see why this needs a vent.
  • One sterile 3mL cartridge. Ours are sold in 10 and 20 packs, each individually sealed.
  • Your pen. V2 or V3 — the routine is identical.
  • A fresh pen tip, plus alcohol wipes and a clean flat surface to work on.
What's in the box with a V2 pen: cap, cartridge holder, body with the 60-click dial, and the screw rod
The pen arrives assembled: cap, cartridge holder, body, screw rod. Cartridges and tips are sold separately.

Know the parts

Six parts, called the same thing on every page of this Help Center.

Cap The outer sleeve over the cartridge holder. It pulls straight off. It doesn't unscrew.
Cartridge holder The clear tube under the cap. It unscrews from the pen body, and you can see the cartridge through it.
Pen body The aluminum half with the dial knob.
Dial knob At the back of the pen body. Turn it to set the amount: 60 clicks, 0.01 mL each, clockwise to add, counterclockwise to back off. Press its end to dispense.
Plunger The black threaded rod inside the body. It pushes the cartridge's stopper, and it turns as it moves, so never force it straight in.
Tip The screw-on pen needle. Sold separately. A fresh one every session.

Put together, the pen is 6.3 × 0.79 × 0.79 in and weighs about 1.76 oz. It fits in a fridge door with the cartridge loaded.

“Where's my cartridge holder?”

It's in there. Promise. The order of operations just isn't obvious the first time:

  1. Pull the pen apart first. Don't unscrew anything yet — pull straight, and the cap comes off to expose the cartridge holder.
  2. Then unscrew the cartridge holder from the pen body.

If you unscrewed it first by mistake, the cartridge holder is now hidden up inside the cap. No harm done — screw the pen back together, then start again from step 1.

Practice with saline first

Run this whole routine once with sterile water or saline before you do it for real. Fill a cartridge, vent it, seat it, prime it, take it apart. Loading is muscle memory, and ten minutes of practice is the difference between a smooth first session and a wasted cartridge.

Please don't learn on your actual compound. MODTECH isn't responsible for material lost while you're getting the hang of the hardware.

How much a cartridge holds

Cartridge volume 3 mL / 3cc. That is a hard ceiling, not a target — see overfilling.
Per click 0.01 mL, the same as one unit on a standard insulin syringe.
Per full dial turn 0.6 mL — the dial has 60 click-stop increments.
A full cartridge About five full dial turns' worth.
Stopper 11mm long gray stopper. A short-stopper cartridge will not seat in a MODTECH pen, whoever sold it to you.
3 mL cartridge measurements: 11 mm stopper, 11.60 mm barrel outside diameter, 62.30 mm glass height
The stopper length decides whether a cartridge fits, not the 3 mL on the label.

Full cartridge information Compare pen models

2. Loading a cartridge

These steps are written for the Classic sterile glass cartridge — the only kind MODTECH sells, and the one our pens are specified around.

The short version: open the pen, fill a sterile cartridge with a vent in place, drop it into the cartridge holder metal cap first, screw the pen back together, attach a fresh tip, and prime until liquid appears. About two minutes the first time.

Why this needs a vent

A cartridge is a sealed glass tube with a stopper at the bottom. When you push liquid in through the top, the air already inside has nowhere to go. It compresses, pressure builds, and eventually something gives — and what gives is the stopper, which shoots out the bottom and takes your solution with it.

A vent is just a second opening that lets that air escape while liquid goes in. It costs you one insulin syringe and it is the single most important step on this page.

The nine steps

How to load the V2 pen: pull the cap, unscrew the holder, add a cartridge metal cap first, screw it back on
Steps 1 and 9 in pictures: the holder sits under the cap, and the cartridge goes in metal cap first.
  1. Open the pen. Pull it straight apart — do not unscrew it first, or the cartridge holder stays stranded inside the cap. Once the cap is off, unscrew the clear cartridge holder from the pen body.
  2. Reset the plunger. If the black plunger is sticking out of the body, guide it back in and let it rotate as it travels. It rides a corkscrew thread. Forcing it straight in will bend it, and that's avoidable damage rather than a warranty claim. Set the pen parts down on a clean surface.
  3. Draw up your solution. Pull the full volume into your 3–5 mL transfer syringe and set it down on a clean surface while you prep the cartridge.
  4. Expose and wipe the cartridge top. Peel the pouch open at the metal-cap end — the end with the silver ring — and slide the cartridge forward until only that end pokes out. Wipe it with an alcohol wipe and let it dry. The rest of the cartridge stays in the pouch, protected, until it goes into the pen.
  5. Build your vent. Take the 1 mL insulin syringe, pull the plunger all the way out, and strip off every cap and needle guard. You want a bare hollow barrel with a needle on the end.
  6. Set the vent. Push the vent needle through the silver-ring end of the cartridge. That open barrel is now a pressure relief valve.
  7. Transfer slowly. With the vent still in place, insert your transfer syringe right alongside it and push the solution in slowly. You'll hear air hissing out of the vent as you go — that sound means it's working.
  8. Remove the vent first, then the syringe. The self-sealing top closes behind both.
  9. Seat the cartridge and close up. Take the filled cartridge out of its pouch and drop it into the holder metal cap first, so the gray stopper faces the pen body. Thread the holder back onto the body. A new pen can need firm pressure to catch the first thread — start it straight and turn slowly so you don't cross-thread it.

Then prime it. That's section 4, and you should not skip it.

Never fill past 3 mL

3 mL is the maximum, not a goal. The stopper has to stay inside the glass barrel. Push it past the bottom edge and the cartridge won't attach to the pen body correctly, which shows up later as a pen that feels wrong or won't press.

If it does happen: leave the syringe inserted and gently push the stopper back until it sits level with the bottom edge of the glass before you remove anything.

Cartridge information Compare pen models

3. Venting methods

Two ways to solve the air problem. Both are closed systems, so the sterile interior of the cartridge stays protected. Pick one.

Method 1: Vent air displacement (recommended)

The most controlled of the two, and exactly what the nine steps above describe: a 1 mL syringe with its plunger removed acts as an air outlet while the solution goes in alongside it. The result is a steady fill with no back-pressure, and a stopper that stays exactly where you left it.

Method 2: Pump displacement

No second syringe required. Slower, and it needs a lighter touch.

  1. Load a 5 mL syringe with your compound and push every trace of air out of it first.
  2. Insert it into the self-sealing end of the cartridge.
  3. Gently draw the plunger up to pull air out of the cartridge, then release. The pressure difference starts moving compound in on its own.
  4. Repeat the cycle. Each pull-and-release moves a little more compound in and lets air flow back into the syringe.
  5. If flow slows or stalls, switch to short slow pumps and release fully between each one.

Don't rush this one. Fast or forceful plunger movement is the quickest way to dislodge the stopper and lose the fill.

Which one to use

Vent air displacement Pump displacement
Best for First-timers and full 3 mL fills Partial fills, or when you have no spare insulin syringe
Extra equipment One 1 mL insulin syringe, sacrificed as the vent None
Speed Faster Slower
Blowout risk Lowest Higher if you pump too hard
Our take Start here Fine once you've done a few

4. Priming the pen

Priming clears the air out of the cartridge and the tip. Do it every time you load a fresh cartridge and every time you put on a new tip — a new tip starts full of air, even on a cartridge you primed last session.

  1. Screw on a fresh pen tip and remove both the outer cover and the inner needle guard so the needle is exposed.
  2. Hold the pen needle up and thump the glass gently with a fingernail. Bubbles rise to the top.
  3. Dial about 5 clicks.
  4. Still pointing up, press the end of the dial knob. The plunger drives the stopper up and pushes air out through the needle.
  5. Repeat until you see solution at the needle tip and no more air comes out.
Close-up of the V2 dial window showing 60, with the click-stop scale
Each click is a fixed step you can feel. One full turn is 60 clicks, 0.6 mL.

Why the first push is stiff

On a fresh cartridge the first push often takes noticeably more force. You're breaking the stopper loose from the bottom of the glass, and a little extra pressure there is normal.

If it stays stiff on every push after that, something else is going on — start with the troubleshooting guide.

Choosing the right pen tips Troubleshooting guide

5. Using it day to day

Every session after setup

Once the pen is loaded, the routine is the same every time:

  1. Take the pen out of the refrigerator. Cold solution is thicker, so if it presses stiffly, give it time to warm up.
  2. Screw on a fresh, unused pen tip.
  3. Prime the new tip. Needle up, dial a few clicks and press until solution appears at the tip. Every new tip starts full of air. See priming.
  4. Dial your amount. Turn the dial clockwise. Each click is 0.01 mL, the same as one unit on an insulin syringe. Went one too far? Turn it back counterclockwise.
  5. Press the end of the dial knob to dispense. When the dial reaches zero, hold still for about ten seconds before you move the pen. The mechanism has stopped; the fluid hasn't.
  6. Take the tip off and put it straight into a sharps container. The pen goes back in the fridge with no tip on.

Storage between sessions

The pen is built to live in the refrigerator with the cartridge loaded. The solid aluminum body handles cold storage without issue, and it fits in the fridge door. A 3mL cartridge covers many sessions. When it runs empty, swap in a fresh one.

6. Swapping in a new cartridge

When the stopper stops moving and nothing more comes out at the tip, that cartridge is done. The swap is the loading routine again, starting from a used pen.

V2 pen with the cartridge holder off, showing the black screw rod above the dial
Holder off: the black screw rod is the plunger. Guide it back in and let it turn.
  1. Take the tip off and put it in the sharps container.
  2. Pull the pen straight apart, then unscrew the cartridge holder.
  3. Tip the empty cartridge out into the sharps container. It's glass, so it goes in sharps, not the bin.
  4. Reset the plunger. Guide it back into the body and let it turn under your finger.
  5. Fill a fresh cartridge with a vent (steps 3 to 8), drop it in metal cap first, and thread the holder back on.
  6. Fresh tip, then prime. A new cartridge always needs priming.

7. About pre-purged easy-load cartridges

You'll come across “pre-purged” or “easy load” cartridges sold elsewhere, and it's worth understanding what they are even though they aren't what we stock.

The design positions the stopper so that no vent is required. You insert your syringe, apply steady pressure, and the stopper walks down the barrel on its own as liquid enters. It removes the vent step and reduces the chance of a blowout, at the cost of a different set of habits.

We don't sell them

MODTECH stocks Classic 3mL sterile glass cartridges only. We do not sell pre-purged easy-load cartridges. Every instruction on this page is written for the Classic cartridge, and that's the one our pens are specified around.

If you bought your cartridges from us, follow the nine steps and vent them.

If you use them anyway

We can't support hardware we don't sell, but the failure modes are worth knowing if you've sourced them elsewhere:

  • Start with an air-free syringe. Trapped air adds pressure and agitates the solution.
  • Insert straight into the self-sealing top. A nicked stopper won't reseal.
  • Expect resistance at the start. Steady, consistent pressure is what unseats the stopper. After a fill or two you'll know the feel.
  • Slow down the moment the stopper begins to move. Transferring fast agitates the compound.
  • Watch the stopper on full 3 mL fills and never let it travel past the bottom edge of the glass. If it does, leave the syringe in and gently push it back level with the bottom of the barrel.
  • Fill through the pouch. Slide the cartridge forward so only the self-sealing end is exposed through the paper side, fill it, then remove it. Keeps it as sterile as possible.

Fit still applies. Whatever style of cartridge you use, a MODTECH pen takes 3 mL cartridges with an 11mm long stopper and nothing else. A cartridge that doesn't match that spec won't seat, pre-purged or not.

Shop MODTECH Classic cartridges Cartridge information

8. When something goes wrong

What you're seeing Usually because What to do
Stopper pushed out the bottom during the fill No vent, or you injected too fast Start over with a fresh cartridge. Use Method 1 and inject slowly.
Cartridge won't thread onto the pen body Overfilled — the stopper traveled past the bottom edge Reinsert the syringe and push the stopper back level with the bottom of the glass.
You press and nothing happens No cartridge seated, or it hasn't been primed The mechanism needs something to push against. Seat a cartridge, then prime it.
Plunger won't go back into the body You're pushing it straight in Let it rotate as it travels — it's a corkscrew thread. Guide, don't force.
The cartridge holder has disappeared You unscrewed the pen before pulling it apart Screw it back together, then pull straight apart first.
Still getting air at the needle tip Not enough priming cycles Keep going with the needle pointed up until solution appears.
First push feels very stiff The stopper is breaking loose from the bottom Normal on a fresh cartridge. See above.

Full troubleshooting guide Safety and warnings

9. Why a pen instead of a vial and syringe

MODTECH V2 pen in silver and V3 pen in matte black, lying flat
  1. 01

    Prep time

    Vial + syringeGather supplies, draw, measure, tap out bubbles, double-check the amount

    MODTECH penFresh tip, quick prime, dial. The same short routine every session

  2. 02

    Measuring

    Vial + syringeTiny graduation marks that are easy to misread

    MODTECH penClick-stop dial with 60 exact increments

  3. 03

    Consistency

    Vial + syringeDepends on technique, angle, and experience

    MODTECH penSame click, same amount, every time

  4. 04

    On the shelf

    Vial + syringeVial, loose syringes, wipes, and a sharps bin to store

    MODTECH penOne pen in the fridge door, a box of tips, and the sharps container you'd have anyway

Compare pen models Shop sterile cartridges