Milligrams in. Clicks out.
Enter what's in the vial and how much bacteriostatic water you added. You get the concentration, and what one click on the dial actually delivers. Add an amount per dispense and you get the clicks to dial for it.
It's arithmetic, and that's all it is. The pen dispenses whatever you put into the cartridge, at the amount you dial, and this page has no more opinion about what that is than the pen does.
Concentration
— mg/mL
One click delivers
— mg
A full turn of the dial
— mg
Volume per dispense
— mL
Clicks to dial
—
Dispenses per vial
—
How the math works
Reconstitution is division. The powder in the vial doesn't change when you add water — you're spreading a fixed amount of material through a known volume, and the concentration is what falls out of that: amount divided by volume.
The pen works in volume, not amount. The dial moves the plunger in fixed 0.01 mL steps, one click at a time, and one click is one unit on a standard 100-unit insulin syringe. The pen has no way to know what's dissolved in there. Concentration is the only thing that turns your amount into a number of clicks.
So the water is the lever. Less water means a higher concentration and fewer clicks per dispense. More water means more clicks for the same material. Neither one is more accurate — you're choosing how finely the dial divides what you already have.
What the dial can and can't do
| The number you got | What it means |
|---|---|
| Under 1 click | Below the smallest step the pen makes. 0.01 mL is the floor and the dial can't split a click. Add more water — the same powder through a larger volume spreads each dispense across more clicks. |
| A fraction of a click | The dial stops on whole clicks only. Round to the nearest one and accept the difference, or change the water so the number lands whole. The calculator tells you which volume does that. |
| Over 60 clicks | Past the ceiling. 60 clicks is one full turn, and that's the most the dial holds at once, so it takes more than one press. Less water pulls the same amount into fewer clicks. |
| Over 3 mL of water | More than a cartridge holds. Split it across two cartridges, or use less water and a higher concentration. |
Where to go next
-
Loading the pen
The full routine for filling a cartridge, venting it and priming — before the first click counts for anything.
-
Cartridge information
Glass and stopper spec, how ours are sterilized, and how much you actually get out of a 3 mL fill.
-
Pen models
V1, V2 and V3 side by side. Same cartridge, same 60-click dial, and no "more accurate" model.
-
Troubleshooting
A stiff press, a drip after dispensing, or a dial that won't move — what to check, and in what order.
-
Sterile 3mL cartridges
Borosilicate glass, 11mm stopper, steam sterilized and individually sealed. Fits V1, V2 and V3.
-
Pens and kits
Every pen takes the same cartridge and the same 60-click dial. Pick on looks and price.